Authors list

When you go into the Tools menu and click into Self Check, a number of codes will appear. These are:

  • rtc - Real Time Clock, the internal clock module that keeps time for the station

  • temp - Temperature, the internal temperature sensor on the FieldKit Upper board

  • bg - Battery Gauge, the chip that reads the battery voltage

  • sg - Solar Gauge, the chip that reads the solar voltage

  • qspi - the QSPI bus, which controls the on-board storage

  • spi - the SPI bus, which moves data to and from the on-board storage

  • wifi - the WiFi module, which allows communication with the app

  • gps - the GPS module, which allows for the station to set its own clock and record its position

  • sdo - SD card open, whether the SD card is present

  • sdw - SD card write, whether the SD card can be written to

  • bpm - Backplane Multiplexer, the chip that tells the module boards which one should be speaking the the main microcontroller at a given time

  • bps - Backplane Shift Register, the chip that handles data moving to and from the module boards

  • led - the LED controller, which handles the color and illumination of the status LEDs underneath each of the module boards

  • lora - the LoRa module, which allows radio communication over longer distances

  • 00X00 - Module Board Status, which shows occupied module bays as an X, and unoccupied bays as a 0, in the order of bay 0-4, where the four are on the module base

If a particular code is highlighted with a white box around the text, then it means that subsystem isn’t working properly. Our team may ask you to do this and report in!